Treatment : spheroidised
Magnification : 50 : 1
Etching medium : 3 % alcoholic nitric acid
Sampling / Specification : transverse
Testing result :
strong surface decarburization ca. 0,50 mm deep |
Treatment : spheroidised
Magnification : 100 : 1
Etching medium : 3 % alcoholic nitric acid
Sampling / Specification : transverse
Testing result :
strong surface decarburization ca. 0,50 mm deep |